Site · SE4
SITE-SE4-00477
Residence Malmö. The control plane steers the whole site — not just the GPUs.
Location
Malmö
Grid area SE4
Grid connection
25 A
11 kW available
Internet
Fiber 1 Gbit
Site owner
Privat host
Agent AGENT-SE4-00477
Site topology
Grid · import 5.7 kW
SITE-SE4-00477
GPU CLUSTER
1 GPU
RUN · 0.7 kW
BUILDING LOAD
2 kW
BASELINE · 2 kW
BATTERY
15 kWh
IDLE · 0 kW
SOLAR
10 kWp
IDLE · 0 kW
EV CHARGER
1 chargers
LIMIT · 3 kW
Assets and ownership
| Asset | Type | Make / model | Capacity | Power | Owner | Status | Telemetry | Markets |
|---|---|---|---|---|---|---|---|---|
| SITE-SE4-00477-GPU | GPU_CLUSTER | NVIDIA L40S | 1 GPU | 0.8 kW | Host-owned | MAINTENANCE | powerKw 0.1 · utilPct 0 · tempC 25 · inUse 0 | COMPUTE |
| SITE-SE4-00477-GRID | GRID_CONNECTION | DSO 25 A main fuse | 17 kW | 17 kW | Privat host | ONLINE | importKw 0 | — |
| SITE-SE4-00477-LOAD | BUILDING_LOAD | — Building load | 2 kW | 2 kW | Privat host | ONLINE | powerKw 2 | PEAK_REDUCTION |
| SITE-SE4-00477-BAT | BATTERY | Huawei 15 kWh LFP | 15 kWh | 8 kW | Privat host | ONLINE | socPct 35 · powerKw 0 · mode idle | FCR, AFRR, MFRR, PEAK_REDUCTION, SPOT_ENERGY |
| SITE-SE4-00477-PV | SOLAR | Fronius 10 kWp array | 10 kWp | 10 kW | Privat host | ONLINE | powerKw 0 | SPOT_ENERGY |
| SITE-SE4-00477-EV | EV_CHARGER | Easee 1 × 11 kW | 1 chargers | 11 kW | Privat host | ONLINE | powerKw 6 | PEAK_REDUCTION, MFRR |
Each asset can have its own owner. Control plane: Kraftnod.
Maximize value per connected kW
Kraftnod Optimizer — decision
Available site power: 9 kW
Option ARun compute2.99 SEK/kWh
Kraftnod Marketplace net 9.32 SEK/GPU-h × demand 28%
Option BCharge battery0.99 SEK/kWh
Shift to evening peak 1.88 SEK/kWh, 88% round-trip
Option CReserve battery for FCR1.93 SEK/kWh
FCR 483 SEK/MW/h, 0.25 h energy reserve
Option DIdle / grid only0.00 SEK/kWh
Baseline
DecisionRUN COMPUTE
- Spot now
- 0.75 SEK/kWh
- Evening peak
- 1.88 SEK/kWh
- Battery SOC
- 35%
- Grid limit
- 11 kW
- Building load
- 2 kW
Dispatch
| Asset | Action | Power |
|---|---|---|
| GPU cluster | RUN | 0.7 kW |
| Building load | BASELINE | 2 kW |
| Battery | IDLE | 0 kW |
| Solar | IDLE | 0 kW |
| EV charging | LIMIT | 3 kW |
| Grid | IMPORT | 5.7 kW |
Site value
Compute0 SEK
Battery flex2 202 SEK
Peak reduction501 SEK
Solar optimization133 SEK
Total site value2 836 SEK / month
Energy cost−−0 SEK
Net site value2 836 SEK