Kraftnod Platform
Control plane for distributed energy & compute
← Sites
Simulated
Last 30 days · simulated
Site · SE3
SITE-SE3-00463
Example Fastigheter AB – Göteborg. The control plane steers the whole site — not just the GPUs.
Location
Göteborg
Grid area SE3
Grid connection
400 A
179 kW available
Internet
Fiber 10 Gbit
Site owner
Example Fastigheter AB
Agent AGENT-SE3-00463
Site topology
Grid · import 60.4 kW
SITE-SE3-00463
GPU CLUSTER
8 GPU
POWER_CAP · 5.4 kW
BUILDING LOAD
29 kW
BASELINE · 29 kW
BATTERY
400 kWh
IDLE · 0 kW
SOLAR
150 kWp
IDLE · 0 kW
EV CHARGER
8 chargers
LIMIT · 26 kW
Assets and ownership
| Asset | Type | Make / model | Capacity | Power | Owner | Status | Telemetry | Markets |
|---|---|---|---|---|---|---|---|---|
| SITE-SE3-00463-GPU | GPU_CLUSTER | NVIDIA RTX PRO 6000 Blackwell | 8 GPU | 6 kW | Kraftnod AssetCo 02 | CURTAILED | powerKw 0.7 · utilPct 0 · tempC 20 · inUse 0 | COMPUTE |
| SITE-SE3-00463-GRID | GRID_CONNECTION | DSO 400 A main fuse | 276 kW | 276 kW | Example Fastigheter AB | ONLINE | importKw 0 | — |
| SITE-SE3-00463-LOAD | BUILDING_LOAD | — Building load | 29 kW | 29 kW | Example Fastigheter AB | ONLINE | powerKw 29 | PEAK_REDUCTION |
| SITE-SE3-00463-BAT | BATTERY | Huawei 400 kWh LFP | 400 kWh | 200 kW | Example Fastigheter AB | ONLINE | socPct 64 · powerKw 0 · mode idle | FCR, AFRR, MFRR, PEAK_REDUCTION, SPOT_ENERGY |
| SITE-SE3-00463-PV | SOLAR | SMA 150 kWp array | 150 kWp | 150 kW | Example Fastigheter AB | ONLINE | powerKw 0 | SPOT_ENERGY |
| SITE-SE3-00463-EV | EV_CHARGER | Easee 8 × 11 kW | 8 chargers | 88 kW | Example Fastigheter AB | ONLINE | powerKw 33 | PEAK_REDUCTION, MFRR |
Each asset can have its own owner. Control plane: Kraftnod.
Maximize value per connected kW
Kraftnod Optimizer — decision
Available site power: 150 kW
Option ARun compute6.42 SEK/kWh
Kraftnod Marketplace net 14.7 SEK/GPU-h × demand 35%
Option BCharge battery0.71 SEK/kWh
Shift to evening peak 1.35 SEK/kWh, 88% round-trip
Option CReserve battery for FCR1.68 SEK/kWh
FCR 420 SEK/MW/h, 0.25 h energy reserve
Option DIdle / grid only0.00 SEK/kWh
Baseline
DecisionRUN COMPUTE
- Spot now
- 0.54 SEK/kWh
- Evening peak
- 1.35 SEK/kWh
- Battery SOC
- 64%
- Grid limit
- 179 kW
- Building load
- 29 kW
Dispatch
| Asset | Action | Power |
|---|---|---|
| GPU cluster | POWER_CAP | 5.4 kW |
| Building load | BASELINE | 29 kW |
| Battery | IDLE | 0 kW |
| Solar | IDLE | 0 kW |
| EV charging | LIMIT | 26 kW |
| Grid | IMPORT | 60.4 kW |
Site value
Compute0 SEK
Battery flex47 192 SEK
Peak reduction12 359 SEK
Solar optimization2 092 SEK
Total site value61 643 SEK / month
Energy cost−−0 SEK
Net site value61 643 SEK