Site · SE2
SITE-SE2-00596
Example Fastigheter AB – Östersund. The control plane steers the whole site — not just the GPUs.
Location
Östersund
Grid area SE2
Grid connection
250 A
112 kW available
Internet
Fiber 10 Gbit
Site owner
Example Fastigheter AB
Agent AGENT-SE2-00596
Site topology
Grid · import 51.4 kW
SITE-SE2-00596
GPU CLUSTER
8 GPU
RUN · 5.4 kW
BUILDING LOAD
39 kW
BASELINE · 39 kW
BATTERY
400 kWh
IDLE · 0 kW
SOLAR
150 kWp
IDLE · 0 kW
EV CHARGER
2 chargers
LIMIT · 7 kW
Assets and ownership
| Asset | Type | Make / model | Capacity | Power | Owner | Status | Telemetry | Markets |
|---|---|---|---|---|---|---|---|---|
| SITE-SE2-00596-GPU | GPU_CLUSTER | NVIDIA RTX PRO 6000 Blackwell | 8 GPU | 6 kW | Kraftnod AssetCo 02 | ONLINE | powerKw 3.6 · utilPct 59 · tempC 19 · inUse 5 | COMPUTE |
| SITE-SE2-00596-GRID | GRID_CONNECTION | DSO 250 A main fuse | 173 kW | 173 kW | Example Fastigheter AB | ONLINE | importKw 0 | — |
| SITE-SE2-00596-LOAD | BUILDING_LOAD | — Building load | 39 kW | 39 kW | Example Fastigheter AB | ONLINE | powerKw 39 | PEAK_REDUCTION |
| SITE-SE2-00596-BAT | BATTERY | Huawei 400 kWh LFP | 400 kWh | 200 kW | Example Fastigheter AB | ONLINE | socPct 37 · powerKw 0 · mode idle | FCR, AFRR, MFRR, PEAK_REDUCTION, SPOT_ENERGY |
| SITE-SE2-00596-PV | SOLAR | Fronius 150 kWp array | 150 kWp | 150 kW | Example Fastigheter AB | ONLINE | powerKw 0 | SPOT_ENERGY |
| SITE-SE2-00596-EV | EV_CHARGER | Zaptec 2 × 11 kW | 2 chargers | 22 kW | Example Fastigheter AB | ONLINE | powerKw 1 | PEAK_REDUCTION, MFRR |
Each asset can have its own owner. Control plane: Kraftnod.
Maximize value per connected kW
Kraftnod Optimizer — decision
Available site power: 73 kW
Option ARun compute6.72 SEK/kWh
Kraftnod Marketplace net 14.93 SEK/GPU-h × demand 35%
Option BCharge battery0.32 SEK/kWh
Shift to evening peak 0.60 SEK/kWh, 88% round-trip
Option CReserve battery for FCR1.51 SEK/kWh
FCR 378 SEK/MW/h, 0.25 h energy reserve
Option DIdle / grid only0.00 SEK/kWh
Baseline
DecisionRUN COMPUTE
- Spot now
- 0.24 SEK/kWh
- Evening peak
- 0.60 SEK/kWh
- Battery SOC
- 37%
- Grid limit
- 112 kW
- Building load
- 39 kW
Dispatch
| Asset | Action | Power |
|---|---|---|
| GPU cluster | RUN | 5.4 kW |
| Building load | BASELINE | 39 kW |
| Battery | IDLE | 0 kW |
| Solar | IDLE | 0 kW |
| EV charging | LIMIT | 7 kW |
| Grid | IMPORT | 51.4 kW |
Site value
Compute45 347 SEK
Battery flex47 914 SEK
Peak reduction13 944 SEK
Solar optimization2 012 SEK
Total site value109 217 SEK / month
Energy cost−401 SEK
Net site value108 816 SEK